Altronix AL600ULACM

Specifications

Brand
Altronix
Series
Altronix ACM
Model
AL600ULACM
Form Factor
Indoor wall-mount access power controller with built-in power supply / charger; BC400 enclosure
Input
115 VAC, 60 Hz
Output Configuration
8 independently-controlled fused-relay outputs
Output Voltage
12 VDC or 24 VDC selectable
Total Output Current
6 A continuous
Output Mode
Fail-Safe and / or Fail-Secure (per output)
Output Protection
Fused — 3.5 A per output; ACM8 board main fuse 10 A
Output Conversion
Power outputs can be converted to dry form 'C' contacts
Output Trigger Inputs
Open collector sink or normally open (NO) dry trigger inputs (e.g., from access control panel, card reader, keypad, push button, PIR)
Fire Alarm Disconnect
Latching or non-latching, individually selectable for any or all 8 outputs
AC Fail Supervision
Form 'C' contacts; notification trigger selectable 30 sec (factory set) or 6 hr
Battery Charger
Built-in for sealed lead-acid or gel batteries; max charge current 0.7 A; zero voltage drop on switchover to battery backup
Compatible Devices
Magnetic locks, electric strikes, magnetic door holders

Best Fit & Recommended For

Chicago multi-door commercial access control with up to 8 doors per power controller
Higher-current installations needing 6 A total budget across the door cluster
Condo and HOA building multi-door installs with code-compliant fire-alarm interlock
Parking garage stairwell and entry-door access power
Multi-tenant residential building common-area multi-door power
Office building floor-by-floor access deployments
Hospitality back-of-house multi-door installations
Industrial / warehouse personnel-door multi-output power
Apartment walk-up front and rear entry door power
Property management portfolio standardized multi-door power

Altronix AL600ULACM Access Power Controller

The Altronix AL600ULACM is the 6 A version of the AL400ULACMCB — same 8-output multi-door architecture, but with fused-relay outputs rated 3.5 A each (10 A main fuse) and a higher 6 A total output current budget. Reach for this one when the door cluster’s combined draw is past the 4 A budget of the AL400ULACMCB, or when you want fused-relay outputs instead of PTC-protected ones.

What’s Confirmed by the Official Altronix Spec

These specifications come directly from Altronix’s published AL600ULACM product page:

  • Input: 115 VAC, 60 Hz
  • Outputs: 8 independently-controlled fused-relay outputs
  • Output voltage: 12 VDC or 24 VDC selectable
  • Total output current: 6 A continuous
  • Output protection: fuses rated 3.5 A per output; ACM8 board main fuse 10 A
  • Output mode: Fail-Safe and / or Fail-Secure (per output)
  • Output conversion: power outputs can be converted to dry form “C” contacts
  • Output trigger inputs: open-collector sink or normally-open (NO) dry trigger from access control panel / card reader / keypad / push button / PIR
  • Fire alarm disconnect: latching or non-latching, individually selectable per output
  • AC fail supervision: form “C” contacts; trigger 30 sec (factory) or 6 hr
  • Battery charger: built-in for sealed lead-acid / gel batteries; max 0.7 A; zero voltage drop on switchover to battery backup
  • Enclosure: BC400 indoor wall-mount

AL600ULACM vs. AL400ULACMCB — Pick Per Current Budget

FeatureAL600ULACM (this page)AL400ULACMCB
Total current6 A @ 12/24 VDC4 A @ 12 VDC / 3 A @ 24 VDC
Outputs8 fused-relay8 PTC auto-resettable
Per-output rating3.5 A fused2.5 A PTC
AC fail supervisionYes — form ‘C’ contacts(per Altronix spec)
Best fitHigher-current 8-door clusters; fused-relay preferredStandard 8-door clusters; PTC auto-reset preferred

Where the AL600ULACM Wins in Chicago

  • Higher-current multi-door commercial access control with up to 8 doors
  • Condo / HOA buildings — common-area doors with code-compliant fire-alarm interlock
  • Parking garages — stairwell and entry doors on one controller
  • Multi-tenant residential building common-area multi-door power
  • Office building floor-by-floor access deployments
  • Hospitality back-of-house multi-door installations
  • Industrial / warehouse personnel-door multi-output power
  • Apartment walk-ups — front and rear entries fed from a single panel location
  • Property management portfolio standardized multi-door power
  • Installations needing AC fail supervision form ‘C’ contacts back to the central panel

Local Chicago Coverage

Vidimost installs the Altronix AL600ULACM across the full city of Chicago for higher-current multi-door access control deployments.

Professional Installation by Vidimost

Vidimost LLC installs the Altronix AL600ULACM across Chicago for higher-current multi-door access control deployments. Full-scope service includes site walkthrough, output assignment per door, fail-safe / fail-secure mode selection per door, fire-alarm interlock wiring (per NFPA 101 / IBC), AC fail supervision wiring back to central panel, battery sizing for runtime requirement, and integration with the access control panel and door hardware. Contact us for a free site walkthrough and quote.