Altronix AL600ULACM — 8 Fused-Relay Outputs Access Power Controller (12/24 VDC @ 6A)
Model / Series: AL600ULACM
Eight-output access control power supply — 6 A at 12 or 24 VDC with fire-alarm disconnect and battery charger for multi-door buildings.
We don't just ship boxes — this goes in as part of our access control installation in Chicago work. From the Loop to Rogers Park — see our security work across Chicago.
Specifications
- Brand
- Altronix
- Series
- Altronix ACM
- Model
- AL600ULACM
- Form Factor
- Indoor wall-mount access power controller with built-in power supply / charger; BC400 enclosure
- Input
- 115 VAC, 60 Hz
- Output Configuration
- 8 independently-controlled fused-relay outputs
- Output Voltage
- 12 VDC or 24 VDC selectable
- Total Output Current
- 6 A continuous
- Output Mode
- Fail-Safe and / or Fail-Secure (per output)
- Output Protection
- Fused — 3.5 A per output; ACM8 board main fuse 10 A
- Output Conversion
- Power outputs can be converted to dry form 'C' contacts
- Output Trigger Inputs
- Open collector sink or normally open (NO) dry trigger inputs (e.g., from access control panel, card reader, keypad, push button, PIR)
- Fire Alarm Disconnect
- Latching or non-latching, individually selectable for any or all 8 outputs
- AC Fail Supervision
- Form 'C' contacts; notification trigger selectable 30 sec (factory set) or 6 hr
- Battery Charger
- Built-in for sealed lead-acid or gel batteries; max charge current 0.7 A; zero voltage drop on switchover to battery backup
- Compatible Devices
- Magnetic locks, electric strikes, magnetic door holders
Best Fit & Recommended For
Altronix AL600ULACM Access Power Controller
The Altronix AL600ULACM is the 6 A version of the AL400ULACMCB — same 8-output multi-door architecture, but with fused-relay outputs rated 3.5 A each (10 A main fuse) and a higher 6 A total output current budget. Reach for this one when the door cluster’s combined draw is past the 4 A budget of the AL400ULACMCB, or when you want fused-relay outputs instead of PTC-protected ones.
What’s Confirmed by the Official Altronix Spec
These specifications come directly from Altronix’s published AL600ULACM product page:
- Input: 115 VAC, 60 Hz
- Outputs: 8 independently-controlled fused-relay outputs
- Output voltage: 12 VDC or 24 VDC selectable
- Total output current: 6 A continuous
- Output protection: fuses rated 3.5 A per output; ACM8 board main fuse 10 A
- Output mode: Fail-Safe and / or Fail-Secure (per output)
- Output conversion: power outputs can be converted to dry form “C” contacts
- Output trigger inputs: open-collector sink or normally-open (NO) dry trigger from access control panel / card reader / keypad / push button / PIR
- Fire alarm disconnect: latching or non-latching, individually selectable per output
- AC fail supervision: form “C” contacts; trigger 30 sec (factory) or 6 hr
- Battery charger: built-in for sealed lead-acid / gel batteries; max 0.7 A; zero voltage drop on switchover to battery backup
- Enclosure: BC400 indoor wall-mount
AL600ULACM vs. AL400ULACMCB — Pick Per Current Budget
| Feature | AL600ULACM (this page) | AL400ULACMCB |
|---|---|---|
| Total current | 6 A @ 12/24 VDC | 4 A @ 12 VDC / 3 A @ 24 VDC |
| Outputs | 8 fused-relay | 8 PTC auto-resettable |
| Per-output rating | 3.5 A fused | 2.5 A PTC |
| AC fail supervision | Yes — form ‘C’ contacts | (per Altronix spec) |
| Best fit | Higher-current 8-door clusters; fused-relay preferred | Standard 8-door clusters; PTC auto-reset preferred |
Where the AL600ULACM Wins in Chicago
- Higher-current multi-door commercial access control with up to 8 doors
- Condo / HOA buildings — common-area doors with code-compliant fire-alarm interlock
- Parking garages — stairwell and entry doors on one controller
- Multi-tenant residential building common-area multi-door power
- Office building floor-by-floor access deployments
- Hospitality back-of-house multi-door installations
- Industrial / warehouse personnel-door multi-output power
- Apartment walk-ups — front and rear entries fed from a single panel location
- Property management portfolio standardized multi-door power
- Installations needing AC fail supervision form ‘C’ contacts back to the central panel
Local Chicago Coverage
Vidimost installs the Altronix AL600ULACM across the full city of Chicago for higher-current multi-door access control deployments.
Recommended Pairings
- Altronix AL400ULACMCB — lower-current 4 A PTC sibling for smaller clusters
- Altronix AL600ULMX — 5-output 6 A alternative
- Altronix AL400ULX — single-output sibling for one-door applications
- Sealed lead-acid backup batteries sized to runtime requirement
Professional Installation by Vidimost
Vidimost LLC installs the Altronix AL600ULACM across Chicago for higher-current multi-door access control deployments. Full-scope service includes site walkthrough, output assignment per door, fail-safe / fail-secure mode selection per door, fire-alarm interlock wiring (per NFPA 101 / IBC), AC fail supervision wiring back to central panel, battery sizing for runtime requirement, and integration with the access control panel and door hardware. Contact us for a free site walkthrough and quote.
Frequently Installed Together
Altronix
Altronix AL400ULACMCB
Eight-output 12/24 VDC access control power supply with per-door fire-alarm disconnect and battery backup for multi-door buildings.
View →Altronix
Altronix AL600ULMX
Five-output 12/24 VDC power supply, 6 A total — one box feeding several cameras or access panels with clean regulated power.
View →Altronix
Altronix AL400ULX
The Altronix AL400ULX is a single-output power supply / charger for access control, burglar alarm, and fire signaling applications — converts 115 VAC / 60 Hz into a Class 2 power-limited output of either 12 VDC @ 4A or 24 VDC @ 3A. Built-in charger for sealed lead-acid / gel batteries, automatic switchover on AC loss, 13"×13.5"×3.25" wall-mount enclosure. UL294 / UL603 / UL1481 / UL1069 listed.
View →